6.0 GE1, GE2 Zone Regulations (General Employment)
|
6.1 |
LOT WIDTH, AREA, YARDS |
|
Table 3.6.1 |
|
Regulation |
GE1 Zone |
GE2 Zone |
|
Lot Width |
45 m |
15 m(a) |
|
Lot Area |
0.4 ha |
900 m2(a) |
|
Yard abutting Guelph Line |
* * * |
15 m |
|
Yard abutting King Road |
* * * |
15 m |
|
Yard abutting Mainway |
* * * |
6 m |
|
Yard abutting Enfield Road |
* * * |
6 m |
|
Yard abutting Heritage Road |
9 m |
* * * |
|
Yard abutting a street having a deemed width of 26 m or greater |
15 m |
9 m |
|
Yard abutting a street having a deemed width less than 26 m |
9 m |
9 m |
|
Side Yard |
4.5 m |
3 m |
|
Rear Yard |
7.5 m | |
|
Yard abutting a residential zone |
30m | |
|
Yard abutting an 03 zone |
7.5 m | |
|
Yard abutting a pipeline easement |
10 m | |
|
Building setback abutting a creek block |
7.5 m, 4.5 m if block includes 3 m buffer | |
|
Yard abutting a railway right-of-way |
none required | |
|
Separation distance from a railway right-of-way |
30 m for land uses sensitive to Railway Rights of Way | |
|
6 m | ||
|
Footnotes to Table 3.6.1 | ||||
|
(a) |
Lots abutting the north side of Mainway between Guelph Line and Walker's Line: | |||
|
Lot Width: |
30 m | |||
|
Lot Area: |
2500 m2 | |||
|
6.2 |
BUILDING HEIGHT | |
|
On lands abutting a residential zone: |
9 m maximum | |
|
6.3 |
FLOOR AREA |
|
Where the principal use is an Office Use, the Maximum Floor Area Ratio for all uses on the lot shall be 0.5:1. |
|
6.4 |
BUILT FORM | |
|
(a) |
A decorative exterior finish shall be maintained on building elevations: | |
| ||
|
(b) |
Exterior walls facing a residential zone shall have a maximum length of 36 m. | |
|
(c) |
Mechanical equipment or machinery may not be installed or used within 20 m of a residential zone. | |
|
6.5 |
LANDSCAPE AREA AND BUFFER | |
|
Landscape Area: | ||
|
Abutting Heritage Road: |
3 m | |
|
Abutting a street having a deemed width less than 26 m: |
3 m | |
|
Abutting a street having a deemed width of 26 m or greater: |
6 m | |
|
Abutting a creek block or 03 zone: |
3 m | |
| Abutting a PC or P zone |
3 m | |
|
Landscape Buffer: | ||
|
Abutting a residential zone: |
9 m | |
|
6.6 |
PARKING | |
|
(a) |
Parking shall be provided in accordance with Part 1, Subsection 2.25 "Off Street Parking and Loading Requirements" | |
|
(b) |
Parking of trucks and vehicles is not permitted within 15 m of a residential zone when the truck or vehicle exceeds one of the following: | |
| ||
|
6.7 |
OUTDOOR MANUFACTURING |
|
In a GE1 zone outdoor manufacturing is prohibited in a yard abutting a street. |
|
OUTDOOR STORAGE | ||
|
Outdoor storage of materials, equipment, parts, refuse, waste, finished products, unfinished products is not permitted except in accordance with the following regulations: | ||
|
(a) |
On lots less than 4 ha in area Outdoor Storage is not permitted in a front yard. On lots 4 ha in area or greater Outdoor storage is permitted in the front yard but not within the required front yard, provided the outdoor storage area shall be screened from all streets and residential zoned lands; | |
|
(b) |
Outdoor storage is not permitted within 9 m of a residential zone; | |
|
(c) |
All refuse, waste and refuse and waste containers shall be screened such as not to be visible from any street or any residential zone; | |
|
(d) |
Where the principal use is a permitted commercial use, outdoor storage of merchandise kept for retail sale on the premises is permitted provided such outdoor storage is not located within a required yard or landscaping strip abutting a street. Where the principal permitted use is a Motor Vehicle Sales, Leasing Rental and Service, the outdoor storage of motor vehicles kept for retail sale, lease or rental on the premises is permitted within the required yard abutting a street except within the required landscaping area. | |
|
(e) |
All outdoor storage, including storage of refuse or waste, except for a permitted Waste Container Facility, and all outdoor processing or manufacturing, is prohibited at a WasteTransfer Station. | |
|
(f) |
Outdoor storage of materials associated with a permitted Recycling Facility shall not exceed a height of 6 m and shall be enclosed by a 3 m high solid screen fence. | |
|
(g) |
Perishable waste must be kept in refrigerated storage within a building. Alternatively, perishable waste may be stored outside if a deep collection waste disposal system, comprised of a sealed container with a lockable lid located primarily below grade, is used. | |
|
6.9 |
LOADING AND UNLOADING | |
|
(a) |
Loading/unloading docks are not permitted in building elevations facing a street. | |
|
(b) |
Loading/unloading activities are not permitted in a yard abutting a street. | |
|
(c) |
Minimum setback from a residential zone: 20 m | |
|
(d) |
Notwithstanding (c) above, where loading and unloading activities are fully enclosed by a permanent structure, that structure may be setback 9 m from a residential zone. | |
|
(e) |
Loading/unloading docks and activities shall be screened from view from a residential zone. | |
|
6.10 |
RETAIL SALES |
|
A maximum of 15% of the total floor area may be used for the display and retail sale of products manufactured, fabricated, processed or assembled for wholesale purposes on the premises. The maximum may be increased to 25% provided the total floor area is less then 1000 m2. |
|
6.11 |
RESTAURANT DRIVE THROUGH FACILITIES | |
|
(a) |
Where drive through facilities are located in or adjacent to building elevations facing a street, landscaping shall be provided to screen the building elevation from the street. | |
|
(b) |
External conveyor pick-up systems are not permitted in a yard abutting a street and shall be setback 15 m from a residential zone. | |
|
(c) |
Intercom ordering stations shall be setback 15 m from a residential zone. | |
|
6.12 |
FENCING |
|
On lands abutting a residential zone fencing shall be installed along the common boundary with the residential zone and shall have a minimum height of 1.8 m, which may be a solid screen fence or a combination of chain link fence and landscape planting to form a dense year-round screen. |
|
6.13 |
DWELLING UNIT |
|
A Dwelling Unit for a Caretaker or Watchman shall be located within a principal building and shall not exceed 75 m2 in area. | |
|
This page last updated: October 26, 2007 | |